60D0h, 68D0h Touch probe source - AxisX

Selects which AKD2G input is used to trigger the touch probe and capture new data.

See Touch Probes.

AKD2G Values for 6#D0h AKD2G Note
-41 to -42 Z pulse for Axis 1 to 2
-31 to -35 Z pulse for Feedback 1 to 5 As FB1, 2, 4, and 5 do not support Z pulses then these will not be shown. When we support SFA on FB 1 and 2 then Z pulse may be possible. X23 is optional so if not fitted then -33 will not be valid.
-21 to -26 DIO1 to DIO6 When X22 is not fitted options -21 and -22 will not be valid. When X23 is not fitted options -23 to -26 will not be valid.
-1 to -12 DIN1 to DIN12 When X22 is not fitted options -9 to -12 will not be valid.
0 Reserved
1 DIN1. Fast Opto
2 DIN2. Fast Opto
3-4 Reserved
5 Valid if AXIS#.PL.FBSOURCE is using a feedback that supports a Z pulse.
6 to 32767 Reserved

Axis 1

Parameter Index Sub-Index Data Type Float Scale Units Access PDO Mappable SMM Versions
Highest sub-index supported 60D0h 0 Unsigned8 - - Read only No All
Touch probe 1 source - Axis 1 60D0h 1 Signed16 - - Read/Write No All
Touch probe 2 source - Axis 1 60D0h 2 Signed16 - - Read/Write No All

Axis 2

Parameter Index Sub-Index Data Type Float Scale Units Access PDO Mappable SMM Versions
Highest sub-index supported 68D0h 0 Unsigned8 - - Read only No All
Touch probe 1 source - Axis 2 68D0h 1 Signed16 - - Read/Write No All
Touch probe 2 source - Axis 2 68D0h 2 Signed16 - - Read/Write No All